    • 18650/4S2P Li-ion battery Pack 14.8V/5.2Ah
    • Portable Medical equipment battery pack - 18650/4S2P Li-ion battery Pack 14.8V/5.2Ah

    18650/4S2P Li-ion battery Pack 14.8V/5.2Ah

    Portable Medical equipment battery pack

    Model: AY-L04S02-064
    Voltage: 14.8V
    Capacity: 5.2Ah
    Size (can be customized): L74*W72*H38mm
    Cell Model:  
    • Description
    • Get quote
    Sender email add: RE: 18650/4S2P Li-ion battery Pack 14.8V/5.2Ah
    • Portable Medical equipment battery pack

      AY-L04S02-064

      ltem Specification Remark
      Nominal capacity 5.2Ah Sumsung 18650 3.7V 2.6Ah
      Nominal voltage 14.8V 3.7V/1Cell
      Charging voltage 16.8V±0.05V 4.2V/1Cell
      Charging method CC/CV (Constant-current and-Voltage with Limited current
      Standard charging time 2000mA/4hour Battery capacity÷charging current×1.5
      Charging current 2600mA(0.5C) 0~+40℃
      Maximum charging current 5200mA(1C) 0~+40℃
      Continuous discharge current 5.2A(1C) -20~+60℃
      Discharge cutoff  voltage 2.5V 2.5V/lCell
      Short circuit protection Exterior short circuit Automatic recovery
      Intermal resistance ≤200mΩ AC lmpedance 1kHz
      Cycle life ≥500  
      Operating temperature Standard Charge 0~+40℃  
      Standard Discharge -20~+60℃  
      Outline dimension L74*W72*H38mm Length x wide x height
      Pre-wired   Red=Positive,Black=Negative
      Protection Circuit Module: PCM-Li6530-037
      Maximal continuous charging current 10A  
      Maximal continuous Discharging current 10A  
      Over-charge detection voltage 4.25V±0.025V Single cell
      Over-charge release voltage 4.15V±0.05V Single cell
      Over-charge detection delay time 0.5S-1.5S Single cell
      Over-discharge detection voltage 2.50V±0.08V Single cell
      Over-discharge release Voltage 3.0±0.10V Single cell
      Over-discharge detection delaytime 50-150mS Single cell
      Over-current detection 25±5A can adjust
      Over-current delay time 5-15mS  

    Copyright ? 2017 AYAA TECHNOLOGY CO.,LTD. All Rights Reserved. Design By Gemelsoft.

    <input id="w84ge"><s id="w84ge"></s></input>
  • <blockquote id="w84ge"></blockquote>
  • <input id="w84ge"><object id="w84ge"></object></input>
  • <center id="w84ge"><dd id="w84ge"></dd></center>
  • <samp id="w84ge"><samp id="w84ge"></samp></samp>
  • 超凡棋牌游戏